Home  |  About Us  |  Contact Us
Aerocon Panels >> Aerocon Panels - Technical Specification

PROPERTIES

     UNITS

THICKNESS

REMARKS

50mm

75mm

Weight (nom) per sq. m. Kgs 43 60
Axial load / metre width (Sample size - 1500 x 300 mm)

KN/m

53 83 Factor of safety - 2.5
Bending Test (4 point UDL) Uniformly distributed load Kg/m²
                 2.9 M span 73 100 Factor of safety - 2.5
                 1.5 M span 198 265
Flexural Strength/ Modulus of Rupture Kg/cm² 67 58 Typical Test results
Comprehensive Strength Kg/cm² 30 40 Typical Test results
Thermal Conductivity W/mºK 0.22 0.21 BS 4370 - Part 2

Sound transmission class (Typical Test result of Prasar Bharati and National Physical Laboratories)

db 33 36 IS :9901 (Part111) -1981
IS :11050 (Part 1)  -1981
Fire rating* minutes 60 120 BS 476 Part 20 - 22
Surface spread of flame*

Fire Propagation Index (I)*

Ignitability*

Class 1

3.7

Class 'P'
(not easily ignitable)

BS 476 Part 7 - 1971

BS 476 Part 6 - 1981

BS 476 Part 5 - 1968
Note: The above specifications are based on typical test result of AEROCON panels with Flexo-O-Board and are subject to revision.
* As per test result of CBRI
 
 
All Rights Reserved@vrajenterpriseindia.com Designed & Developed By Pushpak Consultancy